Original Publication Date: 10/11/2012
Updated Date: 06/18/2013
When accessing the Configuration utility of a BIG-IP system using a proxy or port translation device, the dashboard may not be accessible.
This issue occurs when the configuration of the device that redirects the access to the Configuration utility is through a port number that is not 443.
You are unable to access the dashboard when accessing the Configuration utility of the BIG-IP system.
As a result of this issue, you may encounter the following symptoms
F5 Product Development has assigned ID 380884 to this issue. F5 has confirmed that this issue exists in the products listed in the Applies To box, located in the upper right corner of this article. For information about releases or hotfixes that resolve this issue, refer to the following table:
| Type of Fix |
Versions Fixed |
Related Articles |
| Release | None | None |
| Hotfix | None | None |
To work around this issue, you can modify the proxy or port translation configuration to use port 443.
Impact of workaround: You will need to have administrative access to the device that configures the proxy or port translation to access to the BIG-IP Configuration utility.