Server/Node Operating System Compatibility
Load balancing of any TCP/IP OS, including Windows® NT, Windows 95, all UNIX platforms, and Mac/OS
Internet/Intranet Protocol Support
Administrative Environment Support
DNS proxy, SMTP, SSH, SNMP, dynamic/static network monitoring, scheduled batch job processing, system status reports, and alarms event notification
Secure SSL browser-based interface, remote encrypted login and file transfer using SSH monitor, BIG-IP® system network monitoring utilities and additional contributed software; SNMP gets and traps iControl API using CORBA & SOAP/XML
ASP (active server pages), VB (visual basic script), ActiveX, JAVA,VRML, CGI, Cool Talk, Net Meeting, Real Audio, Real Video, Netshow, Quick Time, PointCast, any HTTP encapsulated data
Web Server Application Compatibility
Operating Temperature
UL 60950 (UL1950-3)
CSA-C22.2 No. 60950-00 (Bi-national standard with UL 60950)
CB TEST CERTIFICATION TO IEC 950
EN 60950
Electromagnetic Emissions Certifications
EN55022 1998 Class A
EN55024 1998 Class A
FCC Part 15B Class A
Non-operational specification
Before you get started with the VIPRION platform, it is important to understand the power options and requirements. This section describes AC power supply support and cable requirements.
The platform supports one to four AC power supplies. The power supplies are auto-ranging 90VAC to 240VAC input. Each power supply can provide up to 1435W of power at low-line input (90-140VAC) and up to 2390W at high-line input (180-240VAC). One power supply with low-line input can support two blades with no redundancy. Table 8.2 shows recommended power provisioning for low-line input.
The same power supply can support up to three blades with high-line AC input as shown in Table 8.3. Adding more supplies provides levels of redundancy.
The cable supplied with the hardware is a 220V high line input cable. This type of cable requires a NEMA 6-20P wall outlet, or region-specific equivalent. For 115V VAC low line input, a different cable is available which uses a NEMA 5-20P, or region-specific equivalent. Region-specific power cables are available from F5 Networks.
Fully loaded system (4 blades, 4 power supplies): 139 lbs. Half loaded system (2 blades, 2 power supplies, 2 blanks): 105 lbs
To maintain the VIPRION platform, you must be familiar with additional specifications such as acoustic levels, airflow movement, and operational altitude for the VIPRION platform.