Platform Specifications

General specifications for system features

This table lists general specifications for system features for the 10000 Series platform.

Item Specification
Transceiver modules hot swap Support for hot swap of SFP, SFP+, and QSFP+ transceiver modules
Power supply hot swap Support for hot swap of the power supplies
Jumbo frames Support for maximum Ethernet frame size of 9216 bytes and MTU of 9128 bytes
Virtual Clustered Multiprocessing™ (vCMP™) Supports provisioning and managing multiple, hosted instances of the BIG-IP software on a single hardware device
Important: Specifications are subject to change without notification.

Platform hardware specifications - 10000 Series

This table lists hardware specifications for the 10000 Series (10000/10050/10055/10200v-FIPS) platforms.

Item Specification
Dimensions H: 3.45 inches (8.76 cm) x W: 17.3 inches (43.94 cm) x D: 21.4 inches (54.36 cm) (per unit) 2U industry standard rack-mount chassis
Weight 40 pounds (18.14 kg) with one power supply, two hard disk drives, and bezel installed (per unit)

43 pounds (19.50 kg) with two power supplies, two hard disk drives, and bezel installed (per unit)

39.4 pounds (17.87 kg) with one power supply, one solid-state drive, and bezel installed (per unit)

42.4 pounds (19.23 kg) with two power supplies, one solid-state drive, and bezel installed (per unit)

42.6 pounds (19.32 kg) with two power supplies, two solid-state drives, and bezel installed (per unit)

  • Front mount rack brackets add 2 pounds (0.9 kg).
  • Quick install rail kit adds 5.5 pounds (2.27 kg).
Processor 1 x Six-Core Intel® Xeon® processor (total 12 hyperthreaded logical processing cores)
Communication interfaces 16 x 10GbE SFP+

2 x 40GbE QSFP+ fiber ports

1 x 10/100/1000 Ethernet Management port

1 x RJ45 console port

1 x RJ45 failover port

2 x USB 2.0 interfaces

Storage drive capacity 2 x 1 TB hard disk drive (HDD)

1 x 400 GB solid-state drive (SSD) (10050 platform only)

2 x 400 GB solid-state drive (SSD) (10055 platform only)

RAM 48 GB
AC power supply 2 x 850 W 90 - 125 VAC(+/- 10%) or 200 - 240 VAC(+/- 10%) AUTO Switching

2 x NEMA 5-15P power cords

DC power supply 2 x 850W DC

Operating range: 44 to 72 VDC

Minimum start up voltage: 44 VDC

Note: Power supply will not start below 44 VDC.
Important: Specifications are subject to change without notification.
Important: F5® only provides support for F5-branded or F5-provided optical modules.

Platform hardware specifications - 10150 Series

This table lists hardware specifications for the 10150 Series platform.

Item Specification
Dimensions H: 3.45 inches (8.76 cm) x W: 17.3 inches (43.94 cm) x D: 21.4 inches (54.36 cm) (per unit) 2U industry standard rack-mount chassis
Weight 39.4 pounds (17.87 kg) with one power supply, one solid-state drive, and bezel installed (per unit)

42.4 pounds (19.23 kg) with two power supplies, one solid-state drive, and bezel installed (per unit)

  • Front mount rack brackets add 2 pounds (0.9 kg).
  • Quick install rail kit adds 5.5 pounds (2.27 kg).
Processor 1 x 10-Core Intel® Xeon® processor (total 20 hyperthreaded logical processing cores)
Communication interfaces 16 x 10GbE SFP+

2 x 40GbE QSFP+ fiber ports

1 x 10/100/1000 Ethernet Management port

1 x RJ45 console port

1 x RJ45 failover port

2 x USB 2.0 interfaces

Solid-state drive capacity 1 x 800 GB solid-state drive (SSD)
RAM 128 GB
AC power supply (non-NEBS models only) 2 x 850 W 90 - 125 VAC(+/- 10%) or 200 - 240 VAC(+/- 10%) AUTO Switching

2 x NEMA 5-15P power cords

DC power supply (NEBS models only) 2 x 850W DC

Operating range: 44 to 72 VDC

Minimum start up voltage: 44 VDC

Note: Power supply will not start below 44 VDC.
Important: Specifications are subject to change without notification.
Important: F5® only provides support for F5-branded or F5-provided optical modules.

Platform environmental operating specifications

This table lists platform environmental operating specifications.

Item Specification
Operational temperature 32 to 104°F (0 to 40°C)
Note: NEBS platforms meet NEBS requirements per GR-63-CORE.
Operational relative humidity GR-63-CORE table 4-4

5% to 85% (40°C) non-condensing

5% to 90% (40°C) non-condensing for a maximum of
96 hours

Note: NEBS platforms meet NEBS requirements per GR-63-CORE.
Non-operational temperature -40 to 158°F (-40 to 70°C)
Non-operational relative humidity 5 to 95% (40°C) non-condensing
Important: Specifications are subject to change without notification.

Platform power specifications - 10000s/10200v

This table lists power specifications for the 10000s/10200v platforms.

Item Single power supply Dual power supply
Typical power draw (AC power; 50% load; temp 25°C) 110VAC input: 290W

220VAC input: 280W

110VAC input: 295W

220VAC input: 290W

Typical power draw (DC power; 50% load; temp 25°C) 48VDC input: 300W 48VDC input: 320W
Maximum power draw (AC power) 110VAC input: 450W

240VAC input: 430W

110VAC input: 470W

240VAC input: 450W

Maximum power draw (DC power) 48VDC input: 430W 48VDC input: 450W
Typical heat generated (AC power) 110VAC input: 990 BTU/hour

220VAC input: 955 BTU/hour

110VAC input: 1010 BTU/hour

220VAC input: 990 BTU/hour

Typical heat generated (DC power) 48VDC input: 1025 BTU/hour 48VDC input: 1095 BTU/hour
Maximum heat generated (AC power) 1470 BTU/hour 1535 BTU/hour
Maximum heat generated (DC power) 1470 BTU/hour 1535 BTU/hour
Important: Specifications are subject to change without notification.

Platform power specifications - 10050 Series

This table lists power specifications for the 10050 Series platform.

Item Single power supply Dual power supply
Typical power draw (AC power; 50% load; temp 25°C) 110VAC input: 280W

220VAC input: 265W

110VAC input: 290W

220VAC input: 290W

Typical power draw (DC power; 50% load; temp 25°C) 48VDC input: 300W 48VDC input: 310W
Maximum power draw (AC power) 110VAC input: 345W

240VAC input: 315W

110VAC input: 350W

240VAC input: 355W

Maximum power draw (DC power) 48VDC input: 365W 48VDC input: 375W
Typical heat generated (AC power) 110VAC input: 960 BTU/hour

220VAC input: 900 BTU/hour

110VAC input: 990 BTU/hour

220VAC input: 990 BTU/hour

Typical heat generated (DC power) 48VDC input: 1015 BTU/hour 48VDC input: 1050 BTU/hour
Maximum heat generated (AC power) 1065 BTU/hour 1200 BTU/hour
Maximum heat generated (DC power) 1235 BTU/hour 1280 BTU/hour
Important: Specifications are subject to change without notification.

Platform power specifications - 10200v-SSL

This table lists power specifications for the 10200v-SSL platform.

Important: Platforms that contain solid-state drives (SSDs) consume an additional 10W (maximum) per drive over platforms that contain hard disk drives (HDDs), approximately.
Item Single power supply Dual power supply
Typical power draw (AC power; 50% load; temp 25°C) 110VAC input: 290W

220VAC input: 290W

110VAC input: 300W

220VAC input: 300W

Typical power draw (DC power; 50% load; temp 25°C) 48VDC input: 305W 48VDC input: 335W
Maximum power draw (AC power) 90VAC input: 415W 110VAC input: 415W
Maximum power draw (DC power) 44VDC input: 425W 44VDC input: 445W
Typical heat generated (AC power) 110VAC input: 990 BTU/hour

220VAC input: 990 BTU/hour

110VAC input: 1025 BTU/hour

220VAC input: 1025 BTU/hour

Typical heat generated (DC power) 48VDC input: 1045 BTU/hour 48VDC input: 1145 BTU/hour
Maximum heat generated (AC power) 90VAC input: 1420 BTU/hour 110VAC input: 1420 BTU/hour
Maximum heat generated (DC power) 44VDC input: 1450 BTU/hour 44VDC input: 1520 BTU/hour
Important: Specifications are subject to change without notification.

Platform power specifications - 10150 Series

This table lists power specifications for the 10150 Series platform.

Item Single power supply Dual power supply
Typical power draw (DC power; 48VDC; 50% load; temp 25°C) 290W 320W
Maximum power draw (DC power) 380W 400W
Typical heat generated (DC power) 990 BTU/hour 1095 BTU/hour
Maximum heat generated (DC power) 1300 BTU/hour 1365 BTU/hour
Important: Specifications are subject to change without notification.

Safety requirements

This equipment complies with these requirements of the Low Voltage Directive 2006/95/EC:

EC Type Examination Certificates: Master Contract 252302
  CB Scheme  
  EN 60950-1:2006+A11:2009+A1:2010+A12:2011  
  IEC 60950-1:2005, A1:2009  
  CSA 60950-1-07, Including Amendment 1:2011  
  ANSI/UL 60950-1-2011  
Important: Specifications are subject to change without notification.

EMC requirements

USA--FCC Class A, Canada--Industry Canada Class A

This equipment complies with Subpart B of Part 15 of FCC Rules for Class A digital devices, Industry Canada ICES-003, Issue 5. Operation is subject to these two conditions:

  1. This equipment may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

European Union

This equipment complies with these requirements of the EMC Directive 2004/108/EC:

As Telecommunication Network Equipment (TNE) in Both Telecom Centers and Other than Telecom Centers per (as applicable):
Directive Required Limits
ETSI EN 300 386 V1.5.1 (2010)  
EN 55022:2010 Class A
EN 61000-3-2:2006+A1:2009+A2:2009  
EN 61000-3-3:2008  
As Information Technology Equipment (ITE) Class A per (as applicable):
EN 55024:2010  
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009  
EN 61000-3-3:2008  
Important: Specifications are subject to change without notification.

Acoustic, airflow, and altitude specifications

This table lists acoustic levels, airflow movement, and operational altitude specifications for the 10000 Series platform.

Specification type Detail Units Value
Acoustic 1 Front

Left

Right

Rear

Top

dBA

dBA

dBA

dBA

64

64

62

71

64

Altitude 2 Operational

Non-operational

Feet

Feet

13,000

40,000

Airflow 3 Open air CFM 260 (max)
Important: Specifications are subject to change without notification.
Table of Contents   |   << Previous Chapter   |   Next Chapter >>

Was this resource helpful in solving your issue?




NOTE: Please do not provide personal information.



Incorrect answer. Please try again: Please enter the words to the right: Please enter the numbers you hear:

Additional Comments (optional)