This release note documents the version 5.0.7 release of the ARX software. This is a maintenance release. We recommend this release for those customers who want the fixes and enhancements listed in Fixes and Enhancements in This Release.

This release is cumulative, and includes all fixes and enhancements released since version 3.2.3. You can apply the software upgrade to 3.2.3 and later. For information about installing the software, please refer to Installing the Software.

Note: F5 offers both feature releases and maintenance releases. For more information on our release policies, please see Description of the F5 Networks software version number formats.

Contents:

- User Documentation for This Release
- Minimum System Requirements and Supported Browsers
- Supported Platforms
     - New/Updated Certifications
- Installing the Software
     - Configuration Changes
- Fixes and Enhancements in This Release
- Fixes and Enhancements in Prior Releases
     - Version 5.0.6
     - Version 5.0.5
     - Version 5.0.1
     - Version 5.0.0
     - Version 4.1.3
     - Version 4.1.1
     - Version 4.1.0
     - Version 4.0.1
     - Version 4.0.0
- Required Configuration Changes
     - Verify that All Proxy Users Use an FQDN Domain
     - Windows 2003 Clusters
     - For Upgrades from Before 5.0.1
     - For Upgrades from Before 5.0.0
     - For Upgrades from Before 3.2.0
- Optional Configuration Changes
- Known Issues
- Workarounds for Known Issues
- Contacting F5 Networks


User Documentation for This Release

In addition to these release notes, the following user documentation is relevant to this release.

These manuals are available from the ARX® GUI or CLI. From the GUI, click on the Documentation link in the navigation panel. From the CLI, use the show software command for a complete listing of the ARX manuals, then use the following command to upload the manual from the ARX:

copy software manual-name destination-url

You can also find the product documentation on the F5 Online-Knowledge Base web site, along with an extensive solutions database.

[ Top ]

Minimum System Requirements and Supported Browsers

The minimum supported browsers for the ARX GUI are:

  • Microsoft® Internet Explorer® (IE), version 6.0
  • Mozilla® Firefox® 1.5, and other browsers that use the Mozilla engine

Later versions are also supported, such as IE 7 and Firefox 3.x.

[ Top ]

Supported Platforms

This release supports the following hardware platforms:

  • ARX®500
  • ARX®1000
  • ARX®4000
  • ARX®6000

New/Updated Certifications

In Release 5.0.7, there are no new and updated certifications.

New/Updated Certifications in Release 5.0.5

In Release 5.0.5, F5 Data Solutions has certified Storwize STN-series appliances for use file servers behind the ARX. Specifically, the certification was for Version 3.5.2.03 with NetApp Data ONTAP Release 7.3.1.1.

New/Updated Certifications in Release 5.0.0

In Release 5.0.0, F5 Data Solutions has certified Windows 2008 for use as both a file server (behind the ARX) and as a client machine (in front of the ARX).

NOTE: Windows 2008 has not been certified as a Domain Controller (DC) in the ARX's Domain.

Windows Filer Servers that Support ARX Snapshots

The following Windows file servers have been certified for use with ARX snapshots:

  • Windows Server 2003
  • Windows Server 2008

The ARX manages snapshots on these file servers through Windows Remote Management (WinRM). This is included with Windows Server 2008, but you must install it on a 2003 server. After installation, create at least one WinRM listener, listening on HTTP port 80 (encrypted or unencrypted). Whether or not the HTTP connection is encrypted, the ARX authenticates through Kerberos. You must use WinRM v1.1 or later

New/Updated Certifications in Release 4.1.0

In Release 4.1.0, F5 Data Solutions certified the following file servers and client machines for use with the ARX.

Filers and File Servers

F5 has tested and qualified Data ONTAP Release 7.3 and 7.3.1 for use on the following back-end filers:

  • NetApp, and
  • IBM N Series.

F5 has also tested and qualified EMC DART 5.6 for use as a back-end file server.

Client Machines

F5 has tested and confirmed the interoperability of the following client software with the ARX:

  • Mac OS X 10.5.5 with
  • Thursby DAVE 7.1.2.

Release 4.1.0 also supports photocopier/scanners as CIFS clients. These scanners can use their "Save As" feature to save a scanned image to a file on an ARX share. The ARX namespace must have a security setting disabled through the CLI (with the new cifs anonymous-access command) or the GUI to support this option.

F5 Data Solutions has tested and qualified the following Kyocera photocopiers/scanners:

  • KM-C2525
  • KM-C3232
  • KM-C3232E
  • KM-C4035E

New/Updated Certifications in Release 4.0.0

For Release 4.0.0, F5 Data Solutions tested and qualified the following 10-gigabit-networking devices with the ARX®4000:

  • F5 BigIP
    10GBASE-SR JDS Uniphase XFP F529937700F4
  • Cisco 4948
    Cisco X2 SR 10-gig Module
  • Force 10 S50N
    10-gig SR Module
  • SMC 8708L2
  • Chelsio NIC
    10GBASE-SR Intel XFP MYBG69N90U
  • Extreme 10G4Xa
    10GBASE-SR Intel SR XFP MYBG71G81W
  • Intel NIC
    10GBASE-SR Infineon XPAK 01564948
  • Netgear GSM7328S
    10GBASE-SR Netgear XFP SR AXM751
  • Netirion NIC
    10GBASE-SR Infineon XPAK 01564948
  • Nortel 5530-24TFD
    10GBASE-SR Intel SR XFP MYBG71G81W
  • Nortel 4526GTX-PWR
    10GBASE-SR Intel SR XFP MYBG71G81W
  • HP Procurve 2900
    10GBASE-SR Procurve X2 DE523RQ001
  • HP Procurve 3400
    10GBASE-SR Procurve X2 DE523RQ001
  • HP Procurve 3500
    10GBASE-SR Procurve X2 DE523RQ001
  • HP Procurve 4205
    10GBASE-SR Procurve X2 DE523RQ001
  • HP Procurve 5400
    10GBASE-SR Procurve X2 DE523RQ001
  • HP Procurve 8100
    10GBASE-SR Procurve X2 DE523RQ001

New/Updated Certifications in Release 3.2.1

In Release 3.2.1, F5 Data Solutions certified the following file-server operating systems for use with the ARX:

  • NetApp Data ONTAP Release 7.2.4 for CIFS-only, NFS-only and Multi-protocol
  • NetApp Data ONTAP Release 7.2.5 for CIFS-only, NFS-only and Multi-protocol
  • EMC Celerra 5.5 for CIFS-only, NFS-only and Multi-protocol
[ Top ]

Installing the Software

For an existing installation, you can upgrade to 5.0.7 from any of the following releases:

  • 5.0.6
  • 5.0.5
  • 5.0.1
  • 5.0.0
  • 4.1.3
  • 4.1.1
  • 4.1.0
  • 4.0.1
  • 4.0.0
  • 3.2.3

For installation instructions, refer to the Upgrading Software chapter in the CLI Maintenance Guide. If you must upgrade from an earlier Release (such as 2.07.001) or an interim release (such as 4.1.0), upgrade both peers to one of the above 3.x or 4.x releases before upgrading them both to the current release.

Configuration Changes

Once you install the software, refer to the Required configuration changes section, which contains important information about changes you must make before using the new software.

[ Top ]

Fixes and Enhancements in This Release

Release 5.0.7 is a Maintenance Release for the 5.00.nnn series of software releases. It does not include any new features or enhancements beyond those of Release 5.0.5. It contains the following fix:

343468
Namespace software could potentially fail and produce a core-memory file during a NetApp import. This occurred when the imported share had a qtree that case-collided with an already-imported directory; for example, when a qtree named /myqtree was imported into a volume that already contained a directory named /MYQTREE.This problem was fixed by updating the code handling this scenario, using changes from the 5.1 release codebase.

[ Top ]

Fixes and Enhancements in Prior Releases

The current release includes the fixes and enhancements that were distributed in prior releases, as listed below. (Prior releases are listed with the most recent first.)

Version 5.0.6

This is another Maintenance Release for the 5.00.nnn series of software releases. It did not include any new features or enhancements beyond those of Release 5.0.5. It contained the following fixes, also included in the current release:

337998
A customer noted six cores. This was fixed by adjusting the loop count to 10000 in the code.

36812
Policy rules were stuck in a "Migrating" state after all selected files moved.

38997
When attempting to nfs-param rsize & wsize for presentation volumes it failed. The nfs-param code has been changed to update the share_genid of all the shares in the volume when the rsize and wsize is changed. This way the next time the connection is used it re-fetches the root filehandle and rsize and wsize information.

37222
The CLI daemon now correctly reports that no transactions are left after completing CLI commands.

38433
The file tracking archive behavior was holding database transactions open for so long. We now use a separate transaction for each rule. This limits the time a transaction is open to one set of archive operations.

39333
Small IP fragments were being handled incorrectly.

38544, 38346, 38587, 38588
An NSM crash could happen in cases where there are connectivity/networking issues with a domain controller. While waiting for an authorization response from the control plane, the back-end file server could tear down the TCP connection, causing memory corruption when the domain controller finally responds. The NSM now detects and corrects this situation to properly return an error to the client.

38321
Fix to address SSB read failures and falsely indicating fan failures.

38493, 38615
A problem in which the deletion of a snapshot rule for which there were snapshots present prevented the browsing of other snapshots has been fixed.

39300
The clock on an ARX6000 ASM could drift in time if the SCM did not respond to a request to provide the correct time. ASM clock synchronization function now times out if the response is not received in timely manner.

37598
Added CLI command to optionally change the LACP timeout from "short" to "long".

37892
A customer with an unusual VLAN configuration experienced asymmetric routing issues. This was fixed with a patch.

38232
The ARX didn't do symmetric routing with respect to VIP when NFS clients were on locally attached VLANs. The code change was to give precedence to the per-vlan default route if available.

39386
Erroneous error message (SSRM-0-ERR-SSRM_TOO_MANY_VSRECS) has been removed. This only manifested if multiple volumes used the same metadata share.

337569
An NFS service occasionally created a very large database file, and that file caused reboots to take a very long time. The file grew at a fast rate for NFS clients that mounted, unmounted, and remounted the NFS service at a high frequency. Now, the database file grows at a slower rate for constant NFS mount and unmount operations.

339663
The snapshot-create reports from a file-history-archive rule contained incorrect file-server information for the metadata share. The incorrect information was the filer name and NFS-export name.

339676
When shares in a presentation volume have multiple attach points to managed volumes, the 'show host... path' used to display wrong path information. The fix was to use additional qualifier for the attach name when querying the OMDB for path information.

38041, 37765, 38209, 38864
Using the CLI to copy files within a CIFS namespace sometimes caused an internal database failure.

38739
The ARX now has increased capacity for NFS ACLs from 512 to 1024.

38144
If the Active-Directory (AD) forests were configured manually on the ARX, it was possible to create a CIFS-access problem. The problem was that CIFS clients from trusted domains could not connect to front-end CIFS shares on the ARX.

37350
There was inconsistent output between the global-config and namespace.

38714, 38511, 37020, 336329
The CLI daemon no longer crashes\cores when running "show reports".

38442
If a CIFS-client application sends a packet with a pass-through Information Level, the ARX (which does not support pass-through levels) should reject it with a STATUS_INVALID_PARAMETER response. Before this fix, it was incorrectly responding with STATUS_SUCCESS. This created unpredictable results for the client application.

37955
When DCs in the local Active Directory gave repetitively slow responses to Kerberos/UDP queries, the ARX's network processors sometimes ran out of UDP ports.

39076
When changes are made in a directory, the wrong number of files is returned when doing a directory listing.

38891
System wouldn't boot with long host name. Host names now limited to 32 characters.

38066
The capture session operation unnecessarily duplicates internal TCP-ACK packets, and continues to duplicate them after you stop the capture session. (This duplication does not occur for an ARX500 chassis, or for any capture session that captures packets to/from all proxy-IP addresses.) Now the no capture session operation stops the internal packet duplication.

38131
Large numbers of TCP duplicate packets were being generated and were visible in network traces. This has been corrected.

39599, 338787, 339803
Watchdog timeouts caused two NSM cores. The code was fixed by changing the timer from 32bit to 64bits.

39508, 336278
Delayed acknowledgement methodology caused NFS migration performance problems.

37047
An internal error caused the show chassis command to hang, and it caused the ARX to send fanFail traps.

36868
The managed-volume software failed and generated a core-memory file during import. This problem has been fixed.

37382
A snapshot remove operation for a particular back-end share would always time out after 50 seconds. This was insufficient for some back-end servers. After your ARX gets the fix for this issue, F5 Support can set a higher timeout for snapshot-related commands if required for your site.

37387, 38238
When a shadow-copy operation copied a file over 4 Gigabytes, it occasionally failed and produced a large core-memory file. This issue was related to issue 35679.

37482
Users were unable to view the contents of the snapshots from the previous version tab. When they clicked on the snapshot, it produced an error.

37522, 38337
A customer experienced an XSDD core.

37653
A crash resulting from race condition during file attributes update no longer occurs.

37855
There was a bug in the ARX500 Macau FPGA upgrade handling.

37904
A fix to ensure a user can browse into a newly created snapshot entry.

38536, 38574
Enhancement to provide CLI option to change the Minimum Retransmit Timeout (RTO Min) in effort to better manager packet retransmissions.

Version 5.0.5

Release 5.0.5 included the following fixes and enhancements, which are incorporated into the current release:

Features

ARX v5.0.5 was a maintenance update that provided support for new ARX4000 hardware; specifically a new control plane with new power supplies.

You can identify whether or not you have the new hardware by a physical examination. The original version of the ARX4000 used a commodity server (control plane), containing six 3 1/2 inch disk drives. (The serial numbers of these commodity servers start with BZDS.) The new ARX4000 uses an F5 Networks purpose-built chassis (control plane) that contains two 2 1/2 inch disk drives. (The serial numbers of the new chassis start with 0200.)

If your installation has upgraded existing ARX4000 systems instead of upgrading to the new platform, the ARX4000 documentation for v5.0.5 contains some information that does not apply to your model. For former versions of the ARX4000 chassis, consult:

  • Rev E of the ARX4000 Hardware Installation Guide
  • Rev C of the ARX4000 Installation Card

These are included in your 5.0.5 release; you can retrieve these earlier versions from the GUI or download them from the CLI.

Fixes

Release 5.0.5 added the following fixes to the ARX:

34347
If you issue a Snapshot Remove command, then all of the contents of the virtual snapshot you are removing will be removed regardless of the current snapshot contents settings.

35115
Spurious battery temperature values were being reported. These incorrect values will no longer be reported.

35243
There was an error in CPU speed calculation logic. Now the CPU speed is correctly reported.

35245
Previously, deleting a report would only unlink the report name from the file system. The disk space for the report file would only be freed when all references to that report were removed (unlinked). Other references to a report could include being opened for copying or collection, and so on.
 

Now, when a report is deleted, it is first truncated meaning that the report is terminated. There can be no remaining references to the report. After that, when the report file is removed, not only will its name be removed from the file system but its disk space will be freed immediately. Therefore, there can now be no discrepancy between the amount of disk space that is reported for /acopia/reports before and after the switch is reloaded.

35266
The ARX Manager can take a null pointer exception while editing an Export due to Back button use. Do not use the Back button in releases prior to 5.0.5. You can use the back button in 5.0.5 and higher.

35313
The "no ip address" command NTLM authentication server was not fully implemented. This operation is now allowed as long as the NTLM authentication server is not in use by a namespace.

35314
Previously, the maximum snmp-server entry limit was being checked prior to adding and deleting an entry. If the maximum snmp-server entry limit had already been reached, the operation failed. The fix was to only check the limit when adding a new entry.

35493
ARX 4000+ Control plane power supply LEDs do not change to amber (or otherwise indicate failure).
 

It is difficult to detect a power supply fan failure on the new ARX4000 control plane. The control plane power supply LEDs do not change color or indicate failure in any way that you can detect visually. However, if you think a fan failure has occurred, you can inspect each power supply fan to determine if the fan is dead and to detect air movement (or the lack of air movement).
 

If you have access to the CLI, enter the show chassis chassinfo command which shows the status of all 4 power supplies. It is best not to rely on the LEDs because the LED states are different for each power supply manufacturer.

35505
Prior to release 5.0.5 the ARX4000 power supply numbering was inconsistent between the data plane and control plane.

Prior to 5.0.5, when facing the back of the ARX4000, the control plane power supplies were designated 1/1 (top) and 1/2 (bottom). The data plane power supplies were designated left-to-right as 2/2 and 2/1, respectively.

Starting with 5.0.5, the ARX4000 includes a new control plane (with new power supplies) and a re-numbering of the data plane power supplies. When facing the back of the box, the control plane power supplies are designated left-to-right as 1/1 and 1/2, respectively. The data plane power supplies are designated left-to-right as 2/1 and 2/2, respectively.

When upgrading an existing ARX4000 to 5.0.5, take note of these changes. If you experience a data plane power supply failure and consult the output of the show chassis chassinfo, it reflects the new designations. For example, the following output indicates a failure of the left-hand data plane power supply:

minturnA# show chassis chassinfo

 Identification:
 Hostname                             UUID
 ------------------------------------ --------------------------------------
 minturnA                             3d17e8ce-571e-11dc-9852-ef323fbb290f

 Chassis:
 Chassis Type  Model Number                          HW Ver.  Serial
 ------------  ------------------------------------  -------  -------------
 ARX-4000      SR2500ALLXR-F5                                 0200000006

 Chassis Environment:
 Base MAC Address    Power            Fan(setting)    Temperature
 -----------------   --------------   -------------   -------------
 00:0a:49:17:84:00   Online           Online          Normal(<45 C)

 Power Details:
 Supply   State
 ------   -----
 1/1      Online
 1/2      Online
 2/1      Failed
 2/2      Online

35727
An ARX cored during the import of share, due to an uninitialized structure. Import now correctly initializes this structure and this problem has been fixed.

Version 5.0.1

Release 5.0.1 included the following fixes and enhancements, also included in this release.

Features

Release 5.0.1 is functionally equivalent to Release 5.0.0.

Fixes

Release 5.0.1 added the following fixes to the ARX:

31861, 36682
ARX500+ V 5.0.5 quorum disk encrypted-password fails due to length.

36943
When CIFS clients unexpectedly cancelled their connections in the middle of a "find" operation (such as Transaction2FindFirst), NSM software allocated memory without freeing it. If this happened often enough, the ARX sent nsmResourceThreshold traps for the "cifsSidBitmap" resource. Eventually, some CIFS clients were unable to connect. The problem is resolved in this Release.

36965
If a managed volume already imported a share from an NTFS qtree, it was unable to import another share from an NTFS qtree with the "ntfs_ignore_unix_security_ops" option. The new share stayed indefinitely in the "Pending Import" state. This only occurred if the first share was imported before an upgrade and the remaining shares were imported after an upgrade.

35969
In some circumstances shadow volume system could encounter sharing violation error for .acopia_shadow and core. This has been fixed

36116
After an upgrade from 3.2.2 to 5.0.1 some MAC OSX users were not being able to login or they experienced degradation in network response. This issue has been fixed.

35679
An integer overflow prevented the shadow volume copy from copying files over 4G. In addition, there was the large memory consumption by shadow receiver. A fix was put in place to prevent integer overflow when the file size is over 4G. A throttle was implemented to prevent the potential large memory consumption by the shadow receiver.

35944
Previously, a shadow target did not remove old files when it became a target for shadow. This problem has been fixed.

36111
Previously, the Kerberos proxy user seemed to cause the domain controller to log several login errors. This issue has been fixed.

36122
Previously, snapshots configured for 14 day retention were not being removed from the file server and were consuming disk space. This problem has been fixed.

34771
A direct (or presentation) volume could not attach to an NFSv3/UDP export unless the export also supported NFSv2. Direct volumes can now attach to NFSv3/UDP exports whether or not the exports also support NFSv2.

35128
Mac OS X clients using SMB file sharing components that are part of the OS were unable to mount shares hosted on the ARX. This was caused by crash of the NetAuthAgent component on Mac OS X. ARX software in this release works around this problem.

35210
Administrators were unable to change the quorum disk location when the quorum disk was offline. Administrators now can change the location of the quorum disk when it is offline.

Version 5.0.0

Release 5.0.0 included the following fixes and enhancements, also included in this release.

Features

Release 5.0.0 adds the following features to the ARX:

File Tracking
An ARX managed volume moves files through tiers of back-end storage as time passes. Some installations use data-protection systems that perform backups and restores directly on their back-end filers. If a backup occurs on Filer A before an ARX volume migrates some files to Filer B, it is unclear which files should be restored to which filer. The new file tracking application resolves this issue.

You can configure an external file server as a file-history archive and configure a volume's snapshot rules so that they regularly store their file locations in that archive. Later, you can make queries about current file locations as well as their locations as they moved from tier to tier in the past. From the GUI, access the File History Query option from the navigation pane. From the CLI, use the commands described in the chapter, Tracking Files on your Back-End Storage in the CLI Maintenance Guide.

Seamless Managed-Volume Import
Previous ARX-software Releases blocked certain client operations, such as renaming directories, while a managed volume imported storage from its file servers. Release 5.000.000 lifts all client restrictions during a managed-volume import, so that clients can access the managed volume's storage as soon as it is enabled.

Kerberos Authentication for the ARX Proxy User
An ARX proxy user is a set of Windows credentials (a username, Windows domain, and password) that a managed volume can use as its identity for autonomous operations. A proxy user in previous releases always authenticated with back-end file servers using NTLM; as of Release 5.0.0, it can use Kerberos as well.

Copying Files Between ARX Maintenance Directories and ARX Volumes
Release 5.0.0 offers a new option for transporting maintenance files: you can transfer them to and from ARX volumes. This is designed for sites that do not permit FTP access (or other Internet access) to their data centers. You can use the copy {nfs | cifs} CLI command, or its GUI equivalent, to copy software-release files, diagnostic files, logs, or other maintenance-related files. Refer to the CLI Reference for detailed instructions on using the CLI command.

New Online Help in the GUI
The 5.0.0 GUI now offers extensive online help, with indexing, book marking, and a search interface. These new navigation tools give administrators the opportunity to pursue any given topic and learn more as needed.

Fixes

Release 5.0.0 fixes the following software issues:

35114
When clients repeatedly performed a metadata modifying operation (create, delete, or rename) on the same file or a permission/attribute modification on the same directory during import, the import software unnecessarily rescanned the modified object's directory. The import software no longer performs these redundant scans.

31073
The ARX CLI failed if you entered multi-byte characters (such as Japanese characters) through a terminal emulator that did not support UTF-8.

32636
The output from collect was inaccessible unless you explicitly specified a .tgz extension. The CLI and GUI formerly accepted this directive without the proper extension; the current release prompts for the .tgz extension if it is missing.

25487
The management address for an external filer, set with the ip address a.b.c.d management CLI command, could not be on the out-of-band (OOB) management subnet for the ARX. That restriction is now lifted.

31029
The show ntlm-auth-server status CLI command got an OPEN_SSL_ERROR string if the NTLM-server password was longer than 22 characters. It now allows up to 64 characters, as indicated by the documentation and online help.

32728
If you incorporated a non-existent filer snapshot into an ARX-snapshot rule (with the snapshot manage CLI command), the ARX erroneously created an empty ARX snapshot.

18135
Under rare circumstances, an nsck ... rebuild on a shadow volume made the volume stall in "importing" state.

30634
The ntp server command allowed v1 and v2 of the NTP protocol, two versions that were not supported. The command no longer offers those options.

32570
An ill-timed filer error sometimes resulted in a spurious "Completed" state for a file-placement rule. In the current release, all reports correctly show a failed migration whenever a filer issue causes a failure.

32609
The report for a failed file-placement rule may terminate with the RULE_INTERRUPTED error. This error is designed for rules that were interrupted by configuration changes and reboots. In former releases, it was also inappropriately used for filer errors and connection issues.

32468
The 'Files in Fileset' counter was incorrect in a File-Placement report and the 'show policy' (detailed) output. The counter for 'Files in Fileset' was higher than the actual number of files when it was incorrect. The counter is accurate in the current release.

32473
Incorrect "Snapshot State" appeared in snapshot reports and the output of the "show snapshot" CLI command. The "Snapshot State" of a sparse snapshot should appear as "Sparse" if any of the volume's shares are excluded for any reason. The snapshot state appeared as "Complete" when shares are excluded because of filer configuration. In this release, the snapshot state correctly appears as "Sparse."

30406
Shadow Volume sync performance for ARX4000 was poor compared to that of the ARX6000. Sync performance in the current Release is equivalent between the two hardware platforms.

34528
The output of the show global-config command displayed reserve file settings for direct volumes.

30414
Could not attach directory to . for a Windows file server.

28709
Conflicting place rules caused a deadlock when simultaneously migrating files between two separate share-farms. Each rule was asking the other rule for a particular share's index while holding a lock preventing simultaneous access.

31457
Dual switch reboot fixed by ignoring a latent disk heartbeat, which caused the junior switch to reboot.

31774
Too many alerts sent due to a transaction leak.

27986
Users could not log on due to authentication errors which were fixed with health check and load balancing improvements.

31083
A standard NFS error resulted in extra "DFM_FILE_ASSERT" messages in the syslog. The ARX no longer logs these unnecessary messages.

30780
The nsmResouceThresholdClear trap was clearing alarm conditions that had not-yet been raised by the nsmResouceThreshold trap. Now any nsmResouceThresholdClear trap follows a matching nsmResouceThreshold trap.

30753
When the dncd tried to send message with too many entries it cored. The NSM can only support up to 64K attach points. When processing a directory with a large number of sub directories, break up the request into multiple messages, which will keep dncd from coring.

33403
Previously, there was a problem display the Japanese character set in a share using a MAC 10.4 GUI on an ARX. This issues is resolved now in the handling of the RPC.

33676
Previously, the LED link light did not come on for 100Mbps setting for the 500+. This issue has been resolved.

31513
Removing an empty direct/presentation volume will cause disruption to all clients that are attached to that volume. A message now warns the user when the volume is still in use by an active global service (Virtual Service in ARX Manager) and asks if they want to destage anyway.

29292
Previously, log messages contained the use of forward and back slashes for path names. They used to use forward slashes in some cases and now they are consistent.

33057
Previously, If a file server was very busy, it was slow to respond to CIFS file close messages. Some clients would resend the close if they don't receive a response after some period of time. Multiple closes on the same file identifier would cause the internal state in the ARX to become corrupted resulting in a failure in an NSM processor. This is now resolved.

31779
A shadow-copy rule produced ambiguous errors when its target volume had no more file credits. The errors appeared in the shadow-copy report in the Target Information section, similar to this error:

% ERROR:  (38):
  Read source file attribute data failed; Unable to read file attributes;
File[share-name:file-path]
Open failed; STATUS_SHARING_VIOLATION
File: partial-file-path

Now the report includes a clearer message:

Shadow volume target has no free files

28482
The copy ... ftp CLI command (and its GUI equivalent) occasionally failed with the following error:

FTP Put error: 'remote file appears to be the same as the local file, 
upload is not necessary'.

This rare failure no longer occurs.

30970
The redundancy software did not send an SNMP trap when the heartbeat directory was restricted to read-only access. The heartbeat directory is on the external filer used as a quorum-disk. Now the redundancy software raises the haPairQDiskOffline trap whenever this write failure occurs.

31854
The ARX had insufficient algorithms for checking the health of its remote Domain Controllers (DCs) and for quickly switching to a healthy redundant DC. As of Release 5.0.0, the ARX began using an LDAP query for its health checks, and offers an option to declare a set of "preferred" DCs in a given Windows Domain. The CLI Storage Guide contains instructions for setting DC preferences and changing the timeout for DC health-check queries.

32565
The ARX kept two copies of each core-memory file. Core files contain important diagnostic information for processes that failed; they typically consume large amounts of space on the internal disks. The ARX now keeps only a single copy of each core file.

30293
User access issues resolved by adding a separate auth queue to vcifs. This is used for incoming NEGOTIATE and SESSION SETUP requests.

32534
The Mibs.tgz file, available in the "software" directory, contained the Secure Agent code as well as the MIBs. The Secure Agent packages have been removed from the Mibs.tgz file. They are still available on the ARX, in the "software" directory alongside the Mibs.tgz file.

32080
A file-placement rule kept trying and failing to migrate files after its target share ran out of space.

33058
A syslog message from the policy engine, RULE_UPDATE_INLINE_FAILED, contained cryptic references to internal processes.

30303
If a file server behind an ARX volume ran out of space, directory renames locked out all other client access for 10 to 15 seconds. The directory renames now fail immediately, without locking out clients.

Workaround: Disable the rule that is scanning.

31258
The clear statistics cifs-auth CLI command did not clear all of the CIFS-authentication statistics. The Failure Reason Table at the end of the show statistics cifs-auth output retained its error strings. Now the clear command clears the full contents of the corresponding show command.

29951
The cancel import CLI command (or its GUI equivalent) failed for a share that had not yet started its import scan. This failure made it impossible to cancel the share import. It also prevented future import cancellations and volume controls in the share's volume.

31227
The POLICY_PEP logging component wrote misleading messages to the syslog during normal tiering operation:

DPRulePlaceTag::ValidateTarget(EvaluateFileContext*)[file-path]
        - no target specified.

These messages appeared when the POLICY_PEP component was at a logging level of "debug." They were not errors. We have rewritten these log messages to be less confusing in the current release.

 

30841
This redundancy configuration caused a dual reboot:

  • The quorum disk and a managed volume's metadata share are on the same back-end file server,
  • the metadata share is configured as a "critical resource" on the ARX, and
  • file server goes offline.

In the current release, no reboot or failover occurs.

 

30784
Share discovery used to not preserve back-end share descriptions. When creating ARX exports by scanning back-end storage, the ARX now initializes the ARX export description from the back end. ** Subsequent changes to the ARX export description will NOT be propagated to existing back-end shares or subshares.** .

34180
If a multi-protocol volume had a non-latin1 character (such as a Japanese character) in its name, the volume software sometimes failed and produced a core file. The failure only occurred if the namespace's NFS-side character encoding was set to "iso-8859-1;" from the CLI, you can set this with the character-encoding command.

31292
A reboot issue had no immediately client-visible effects, but had the potential to take services offline at a later time. An NSCK destage of one of the affected volumes could trigger the service loss. (From the CLI, you use the nsck ... destage command to destage a volume.) At the time of the destage, all of the volume's front-end services went offline. The root cause of this outage has been corrected.

27621
The show namespace CLI command and the GUI's Managed Volume Details screen both display the number of files used and files available on a volume's shares. The number in the CLI output was different from that of the GUI; one was rounded and the other was exact. In the current release, the numbers match in both interfaces.

31528
The option to ignore a back-end file/directory name was applied to directories during import, and it was applied to both files and directories after import. The CLI command was named ignore-directory, and its GUI equivalent had a similar name. As a result of this inconsistent treatment of ignored names, a file could successfully import into a managed volume and then be ignored by volume software, making it inaccessible to clients. The CLI command (and function) has been renamed to ignore-name: this command and its GUI equivalent now ignores all directory and file names that it matches.

Version 4.1.3

Release 4.1.3 was a maintenance release that fixed the following software issues:

37890
When using NFS V3 over TCP, and when configuring the ARX to use multiple TCP connections to each file server (a configuration which is not on by default and should be used with caution), the ARX would not send keepalive messages over all of the open connections properly. This would result in connections being torn down by the back-end file servers, which would impact client requests, occasionally making them fail. The keepalive processing now works correctly over all connections making NFS V3 TCP connections much more reliable.

39158
A partner requested we document unsupported releases in Release Notes to clarify upgrade paths. Release notes now contain clear instructions for an upgrade path.

37329, 37333, 39011, 37521
A file-placement rule sometimes stopped migrating with 199 files in a "pending migration" state. This was due to an internal resource-contention issue that is resolved in this release.

37815, 37939
A shadow-copy rule frequently stopped without finishing. This issue occurred when a client renamed a directory in the source volume. This was due to an internal issue that is now resolved.

37512, 34517, 37464, 37472
Some customers experienced that NFS volumes were inaccessible until failover. Several changes have been made to the NFS proxy server and support software to correct the issue.

Version 4.1.1

Release 4.1.1 was a maintenance release that fixed the following software issues:

34445, 37446
The output from show policy sometimes showed a volume as 'offline' when it was not.

36659
A problem in which the ARX erroneously advanced the day of the week by one when setting the time on CIFS clients using NET TIME has been fixed.

36818, 36219
If you enabled a managed volume on an ARX500, failed over to its redundant peer, and then enabled the volume's CIFS service on the peer, the CIFS service sometimes got stuck in the 'starting' state.

36187, 37400
If a back-end server stopped responding to an open CIFS session, and the NSM processor with the CIFS session had an increasing number of client queries for the server, the NSM processor sometimes failed.

36643
Mac OS X 10.4 & 10.5 "DAVE" CIFS clients were losing sight of files and/or folders exported from an ARX service.

35477, 34500
New ARX4000s show NVRAM ECC error until NVRAM cleared.

35521
The internal hard drives supplied to F5 Networks, Inc. for some ARX500s and ARX1000s had a firmware issue. The issue sometimes caused the drives to be remounted as read-only, thereby taking the chassis offline. F5 issued letters to all customers known to have this issue, and replaced the faulty drives.

35947
Previously, when a user tried to find a previous version of a file or directory using the Previous Versions tab in the Properties dialog box from Windows Explorer, some or all of the versions did not appear. In this case, the snapshots were available by browsing the available snapshots in the snapshot directory (whose name is configurable, but is "~snapshot" by default) via the managed volume. This has been fixed.

35140
After the maximum amount of NTP servers were configured, someone attempted to move one and it failed. This command now works as expected, and moving an NTP server is successful.

35486
Previously, a forced storage remove left old replica filehandles around with storage IDs that no longer existed in the volume. This problem has been fixed and old replica filehandles are no longer left behind.

45140
After the maximum amount of NTP servers were configured, someone attempted to move one and it failed. The command now works as expected.

33694
Two administrative operations often resulted in omTransactionsRaise traps from the ARX: those invoked by the collect and remove-share ... migrate CLI commands, or their GUI equivalents.

34855
If a managed volume with browsing enabled was importing when a process requested the volume's free space, the import slowed noticeably.

31748
UPN support. Added UPN support for NTLM.

29219
The cancel sync files CLI command had an issue with command completion. The syntax below showed all volumes on the ARX instead of the set of volumes in namespace:

cancel sync files namespace volume ?

Now the command shows only the list of volumes from the specified namespace.

 

32965
An ARX-snapshot removal is designed to remove each component snapshot from the ARX volume's file servers. If any file server failed to delete its snapshot, the ARX noted the failure and then removed all records of the ARX snapshot from its database. This made it impossible to delete the file-server snapshot from the ARX. Now the delete-snapshot operation keeps the ARX snapshot as a "sparse" snapshot; the sparse snapshot only includes the file-server snapshot(s) where the delete failed.

30951
EMC Checkpoints fail with error "Unable to find file system ID <FSID #>." It is possible that the query can fail to find the file system ID. The usual cause of this problem is that the management IP address set for the external-filer object does not identify the correct EMC Control Station for the file system. To view a list of file system IDs and names, run the command 'nas_fs -list' on the EMC Control Station's management console. If the file system ID reported in the error message is not in the list, then it is likely that the wrong Control Station IP address is configured for the external-filer.

33126, 33676
Previously, the LED link light did not come on for 100Mbps setting. This issue has been resolved.

33024
In a particular VPU configuration, a share-removal operation could cause volume software to restart and produce a core file. The restart occurred for a volume that shared its VPU domain with 63 other volumes. (You can remove a share with the remove-share CLI command or its GUI equivalent.)

32595
A shadow volume sometimes failed if it was backed by an NTFS qtree. The problem was that the shadow-copy rule was using NFS to write its database to the qtree. This release uses CIFS to write the shadow-copy database to an NTFS qtree.

33023
The policy engine failed to detect a rare metadata failure that made it impossible to operate successfully. File-placement rules continued to take CPU cycles without successfully migrating any files. The place rules added many messages to the syslog with this statement: "(No policy queue exists for this volume.)." In the current release, all rule processing stops for a managed volume with this failure.

33706
The snapshot manage CLI command had an unclear error message. The error message is clearer in this release.

33194
An NSM-core processor could fail with a rare combination of NLM transactions (from NFS clients) and file-server outages. These combinations no longer cause an NSM failure.

33312
The snapshot manage CLI command (or its GUI equivalent) failed unless it was preceded by a snapshot create operation in the same managed volume.

33217
When a CIFS-only volume on the ARX attempted to import a CIFS share from a NetApp filer, the import could fail due to an NFS security setting on the filer. The failure occurred only for an ARX volume configured for CIFS subshares, and for a NetApp share backed by a Unix qtree. The NetApp's Unix-security setting is now properly ignored by the CIFS-import process.

Version 4.1.0

Release 4.1.0 included the following fixes and enhancements, also included in this release.

Features

Release 4.1.0 added the following features to the ARX:

CIFS Access-Based Enumeration (ABE) Support
Release 4.1.0 adds CIFS support for Access-Based Enumeration (ABE). If an ARX volume has ABE enabled, its CIFS clients can only see the files that they have permission to read. That is, inaccessible files and directories do not appear in directory listings. This feature is designed to eliminate client curiosity about files and directories that they do not have permission to view.

The following ABE-supporting filers have been qualified for use behind ABE-supporting volumes:

  • EMC Celerra, software version 5.5.
  • NetApp, software versions 7.2.3 and 7.2.5.
  • Windows 2003 R2 SP2.
  • Windows 2003 SP1.

NOTE: For any ABE-supporting volume backed with NetApp filers, the volume's namespace requires a proxy-user with new access privileges. The proxy-user account must belong to the "Administrators" group on each ABE-supporting NetApp share. This is a higher level of access than the "Backup Operator" privileges required for file migrations.

Support for Maximum Age for Kerberos-Machine-Account Passwords
Some Domain Controllers (DCs) support a "Maximum Age" option that you can set for Machine-Account passwords. This is a secret password exchanged between a machine account (such as an ARX-CIFS service) and the DC when the machine/service first joins the Active-Directory domain. By default, the password lasts indefinitely. Administrators have an option on some DCs to set an expiration period, called a "maximum age." If the machine-account password expires for an ARX-CIFS service, the service can no longer use Kerberos to authenticate its CIFS clients.

Release 4.1.0 adds an operation to resolve this issue. For a site where the maximum age is set and about to expire, you can use the cifs rekey CLI command (or its GUI equivalent) to regenerate the key(s) for your ARX-CIFS service(s).

Fixes

Release 4.1.0 fixed the following software issues, also fixed in this release:

35421
On an ARX 6000 system, certain types of network control packets could exhaust all internal memory associated with the networking hardware in the system. No further network communication can occur on this port until an ARX failover is performed.This problem is fixed with this release.

35373
The FILER_CREATE_FILE_FAILED message caused an NSM core. We fixed memory corruption occurring in the NSM logging subsystem when formatting a log message longer than 130 bytes.

30623
A reboot failed to recover an ARX4000 in SSB-degraded mode. SSB-degraded mode means that the PCI connection has failed between the DP and the CP. In this release, the connection recovers after a CLI reload or its GUI equivalent.

32330
The snapshot timeout client-tolerance command is unsupportable in some file-server topologies. The solution to this issue is to automatically generate a suitable timeout value for ARX snapshots, and to deprecate the command.

32086
When an NSM fails in an ARX6000, certain CLI commands and GUI operations hang without ever completing.

31713
When removing a back-end share from a managed volume, a transient connectivity problem with the share's filer can stop the share-removal operation. The share-removal operation now retries for a longer period of time before canceling. (You can invoke a share-removal operation with the no share, no filer, or remove-share CLI commands, or their GUI equivalents.)

32161
Share-removal reports may contain spurious FF ("Found File") entries.

The solution to this problem is to issue a new CLI command, expect change-mfg-date.scr serial-number, where the serial-number is the one on the chassis label. This changes the output of show chassis chassinfo.

32323
Some processes on the SCM or ACM use progressively-more memory, causing the ARX to eventually refuse administrative logins and offer progressively-slower service to its clients.

31240
The ARX supports a single default route; this may be a problem in a multi-VLAN network with a certain firewall configuration.
The new ip route ... per-vlan CLI command allows an administrator to work around this issue. Refer to the CLI Reference for details on this command.

31674
An alarming syslog message, "xsdd_aipc_task: IPC service error 3...," may appear repeatedly on an ARX, often when the ARX is processing a large number of SID translations. This message does not typically indicate a service-affecting problem, so its severity has been downgraded.

31549
The CLI online help does not line up its options with the correct descriptions. For example, the description below should line up with the generic "Text" option instead of the specific "arx.testlab.sg" choice:

my-arx(gbl)# cifs ?
arx.testlab.sg      - Specify the global server hosting this CIFS service.
cifs.arxsg.com      -
nfs1.test.lab       -
Text<1-128>         -

my-arx(gbl)# 

30912
If an ARX with two internal disks (an ARX1000, ARX4000, or ARX6000) loses both of them, it fails to reboot so that its redundant peer can take over its storage services. The resolution to this issue is a proper reboot and a faster failover.

31805
An NSM processor fails and produces a core-memory file if it receives a particular error from a back-end-CIFS filer. This only occurs in a presentation (or "direct") volume.

32224
The following circumstances lead to progressively-more memory consumption on the SCM or ACM processor, 1.1:

  • a presentation (or "direct") volume uses a managed volume as one of its "filers", and
  • that managed volume is deleted.

The bespd daemon uses up progressively-more memory until it fails and restarts. This daemon's memory consumption is visible in the output of the show system task CLI command.

 

31488
If an ARX4000 NSM experiences certain driver issues, the driver writes an excessive number of repetitive log messages to the serial Console. This slows the performance of the network drivers, and masks useful driver logs.

32089
A DAVE 7.x client application can create an issue when opening directories in an ARX volume: if the ARX has a particular failure while opening the directory, the directory remains open after the DAVE client has left it. A directory in this state cannot be deleted or renamed by other clients.

31804
A pair of NSM processors can unexpectedly fail, causing a failover in a redundant pair of ARXes. This is due to the NSM software's incorrect assertion that an internal-memory buffer (for log messages) has overflowed.

31692
The ARX4000 does not reliably process jumbo frames. (You can enable or disable jumbo frames with the [no] jumbo mtu CLI command.)

Version 4.0.1

Release 4.0.1 included the following fixes and enhancements, also included in this release.

Features

Release 4.0.1 is functionally equivalent to Release 4.0.0. Unlike Release 4.0.0, this release has been fully qualified for use on the ARX®6000 as well as all the other ARX platforms.

Fixes

Release 4.0.1 fixed the following software issues. These fixes are also included in the current release:

32049
The ARX does not re-create its error.log or fastpath files if an administrator deletes one of them. (You can delete these files with the delete logs error.log or delete logs fastpath CLI commands, or their GUI equivalents.)

30720
If an ARX runs active VPUs on both redundant peers (configurable only on earlier versions of ARX software), the CLI or GUI may show incorrect used-file credits for those VPU(s).

31162
An NFS-access list with more than 128 IP addresses can cause the ARX to repetitively reboot if it is used in a presentation (or "direct") volume's attach point.

31255
The ARX4000 allows the Control Plane to power up when the Data Plane is powered off and/or disconnected. This is an unsupported configuration that causes a software loop and prevents the ARX from fully booting.

31483
If a client reads or writes a file with a particular byte sequence through an ARX4000 VIP, the ARX stops processing client traffic.

Version 4.0.0

This section describes the features and fixes from Release 4.0.0. Sites that upgrade from Release 3.2.0 and earlier get the benefit of all the features and fixes described here, in addition to the features and fixes described above.

Features

Release 4.0.0 adds the following features:

ARX®4000
Release 4.0.0 supports the new ARX®4000 hardware platform, which is a 4U device with 10-gigabit interfaces. The ARX®4000 has storage capabilities equal to an ARX®6000 with 2 ASMs and 2 NSMs. This platform supports a total of 10Gbps throughput.

Passive LACP
The Link Aggregation Control Protocol (LACP, defined in IEEE 802.3ad) dynamically manages the member ports in a channel. For example, if a configuration change disqualifies a port for channel membership, LACP processes automatically detect the change and stop using the port in the channel. Release 4.0.0 supports passive LACP, which you can configure with the lacp passive CLI command. Refer to the Layer-2 chapter in the CLI Network Guide for details on LACP and LACP configuration.

Fixes

Release 4.0.0 fixes the following software issues:

30441
The policy status showed scan complete/migration complete but the metadata report showed files left on source share.

27757
Deploying switches via template doesn't work with configuration order.

28613
Major inconsistencies revolving around the volume hosting home directories.

28647
When l2 failed on the senior switch, it detected a remote metalog error and causes the junior switch to fail. Since the senior is already rebooting due to the l2 failure, this causes a dual reboot.

29154
Cannot identify volumes using namespace-level metadata.

29416
CIFS AD forest names and Windows domain names are case-sensitive and should not be.

29417
GUI virtual services page does not display "joined" when no exports exist.

29450
A planned ARX reload during a large NTP-time skew can result in an unplanned reboot later.

29454
Remove-share nomigrate incorrectly requires "force" on failed import share. The "remove-share nomigrate" command used by the GUI and from priv-exec at the CLI required the "force" option to remove a share that failed import.

29565
A global server that references only disabled volumes can consume 99% of the CPU.

29667
Scripted creation of a VLAN in the ARX4000 CLI may fail.

29704
Policy is unable to move files from one share to another. When looking at the shares in the managed volume, freespace is being reported correctly, yet when a place rule is enabled, policy is unable to move files.

30269
Can't find active partition in config file.

30454
On the ARX4000, if the data plane is powered up after the control plane, the reload CLI command reboots the control plane but not the data plane.

30296
Cryptic error message needs to be more helpful. Superfluous text removed.

30301
Under cifs-service, the vol-path in the exports command is case-sensitive.

30343
If an NSM core has failed, nsm recovery is disabled, and you create a new CIFS service, the service cannot get past the "Starting" state.

37999, 336537
Under certain conditions, the active ARX global configuration could become corrupted if the initial pairing of an HA pair failed due to timeout conditions. This problem has been fixed, and the active global configuration is no longer affected if the backup ARX does not pair with the active ARX.

[ Top ]

Required Configuration Changes

If you upgrade from 5.0.0 (or later) to 5.0.7, no configuration changes are necessary. If you upgrade from a release earlier than 5.0.0, you require the following configuration changes to support all of the release's new features.

Verify that All Proxy Users Use an FQDN Domain

Any namespace that supports CIFS access has a proxy user that it uses as its identity. The proxy-user configuration is a username, password, and Windows domain that is valid in your Windows network. The proxy user's Domain should always be an FQDN (such as "mysrvr.myco.com") instead of a short name (such as "mysrvr"). This ensures that the ARX can authenticate with Kerberos, which can be vitally important in some situations.

  1. Use show namespace namespace-name to find the name of the "proxy-user" for a given namespace.
  2. Use show proxy-user proxy-user-name to see the configured Windows Domain for the proxy user.
  3. If the Windows Domain is a short name, you can use the windows-domain command in gbl-proxy-user mode to change it to an FQDN. (Use the pre-win2k-name argument if you need to specify both the FQDN and a short name that is completely different from the FQDN.)

Windows 2003 Clusters

If you previously used a Windows 2003 cluster behind a managed volume, you require one of two configurations to continue using the cluster. The first is recommended as a best practice, and the second is for sites where the cluster does not have a shared Service-Principal Name (SPN):

  1. Add the cluster's shared SPN to its configuration on the ARX. From the CLI, you can use the gbl-ext-filer spn command to set this. For example, spn vsrvr@myco.com. This must be a virtual SPN, one that persists after a cluster failover.
    This implies that the cluster's virtual-CIFS service must join the local AD domain. For sites where this is not possible, use the option below.
  2. Do not configure any SPN for the Windows 2003 cluster. This is contrary to the user documentation, which states that an SPN is recommended for any Windows cluster or Kerberos-supporting server.
    From the CLI, you can use the gbl-ext-filer no spn command to remove the SPN configuration.

In either case, you can use the show external-filer command to map the Windows 2003 cluster's VIP to an "external filer" name on the ARX. Then use external-filer filer-name to enter the CLI mode for that filer, and then the spn or no spn command as needed.

For example, the following command sequence finds the external-filer name for a Windows 2003 cluster and sets its SPN:

gffstnA# show external-filer
  Name                       IP Address      Description
  ------------------------   -------------   ----------------------------
  ch-wd-win1                 192.168.158.93  Windows Server 1, back room
  ch-wd-win2                 192.168.158.106 Windows Server 2, cluster next to Win1
  ch-wd-nas                  192.168.158.94  NAS filer in computer lab
gffstnA# global

gffstnA(gbl)# external-filer ch-wd-win2
gffstnA(gbl-filer[ch-wd-win2])# spn fs2k8c95@GGH.MEDARCH.ORG
gffstnA(gbl-filer[ch-wd-win2])# ... 

For Upgrades from Before 5.0.1

This section only applies to installations that upgraded to Release 5.0.0 or earlier.

Once you have installed the software, you must make the following required configuration change(s).

Unicode Upgrade

This section is for administrators who need to upgrade from releases prior to 5.0.0. The 5.0.0 Release includes a new Unicode library that may have an effect on client files and/or directories. The new version of Unicode adds 168 lower-case versions of characters that were uppercase-only in the previous version. The characters derive from the following languages:

  • Native-American languages from modern-day Canada, including SENĆOŦEN.
  • Greek symbols for editorial markings.
  • Cyrillic letters that may not be current.
  • Georgian letters from an ancient ecclesiastical alphabet.
  • Glagolitic letters; Glagolitic is a historical Slavic alphabet.
  • Coptic letters, used by the original Christians in Egypt.

After the upgrade to Release 5.0.0, clients cannot open any files or directories with any of these rare characters in their names. This problem should be very rare. The symptoms are different for files than they are for directories, as explained below. If you see these symptoms on any of your files or directories, escalate the problem to F5 Support.

Files

If a Windows client attempts to open a file with one of these characters in its name, an error similar to this appears in Windows Explorer:

Cannot find the \\VIP\unicode/dir1/file%c8%ba.txt
Directories

Windows Explorer returns the following error if it attempts to open a directory with one of these characters in its name:

Refers to location that is unavailable

For Upgrades from Before 5.0.0

Release 5.0.0 introduces two new maintenance features for shadow-copy rules. If your site uses shadow-copy rules, F5 recommends that you use these features after the upgrade to 5.0.0.

  • Moving the Shadow-Copy Database to the Metadata Share
    You can now place a rule's shadow-copy database on the target volume's metadata share. In previous releases, the shadow-copy database resided on the same back-end filers that held the target volume's copied files. As the set of copied files expanded, it became possible to run out of space on the target filer(s), thereby possibly corrupting the database. The shadow volume's metadata does not grow as fast as its user data, and there are SNMP traps to alert you of free-space issues on that share, so the metadata share is typically a better candidate for this database. From the CLI, you can go to gbl-ns-vol-shdwcp mode and use the database-location metadata-share command to move the shadow-volume database the next time the rule runs.
    This is only necessary for a shadow-copy rule from before the 5.0.0 upgrade. The next time the rule runs, it migrates the database to the metadata share.
  • Shadow Copying Names that Match the CIFS "8.3" Pattern
    This option only applies to an ARX volume that supports CIFS. CIFS-supporting filers typically create an alternate name for any file or directory whose name is longer than eight characters, or whose extension is longer than three characters. The alternate name matches the old-style "8.3" pattern, with up to eight characters that are optionally followed by a "." and up to three more characters. Typically, filers include a tilde (~) in this alternate name. If a real name on the source volume matches one of these alternate names in the shadow volume, the shadow-copy rule refuses to copy the file by default. This is a rare circumstance, but it is possible in any CIFS volume.
    You can change this with a new feature in 5.0.0. From the CLI, you can go to gbl-ns-vol-shdwcp mode and use the cifs-8dot3-resolution command to make the copy possible without overwriting the file with the alternate name.

Refer to the CLI Reference Guide for details on both of these commands.

NOTE: These are not strictly-required configuration changes, but F5 strongly recommends them for customers that use shadow-copy rules on the ARX.

For Upgrades from Before 3.2.0

This section only applies to installations that upgraded from Release 3.1.0 or earlier.

Once you have installed the software, you must make the following required configuration change(s).

For Sites with Windows Filers, New Filer Setting Required for NTLM Connections
Before Release 3.2.0, the ARX used "non-extended security" for its NTLM-authenticated connections to back-end filers. To correct Issue 27316, the ARX started to use "extended security" for its CIFS connections. However, newer Windows servers require NTLMv2 (not NTLM) for its "extended security" connections. To prepare for an upgrade to Release 3.2.0+ in an installation with Windows filers, verify that the following parameter (from the Windows security-policy UI) allows NTLM connections:

Network security: minimum session security for NTLM SSP based clients.

This policy parameter should be set to "No minimum;" none of the four flags for this parameter should be raised.

The following parameter must also be set so that it does not refuse NTLM from clients (such as the ARX). This was required for ARX Releases before 3.2.0, so you only need to investigate this for new Windows filers or new ARX installations:

Network security: LAN Manager authentication level

You must reboot the Windows server for this (or these) changes to take effect.

NOTE: Windows 2008 clients and Windows Vista clients require similar changes to authenticate to ARX services with NTLM. In a typical installation, these clients use Kerberos authentication; no change is required for Kerberos.

[ Top ]

Known Issues

The following items are known issues in the current release.

Workaround: Cool down the box and then reload or power cycle.

The ARX4000 Data Plane (NSM side) cannot recover from a power failure until the Control Plane (ASM and SCM side) reboots. (29444)
If the Data Plane (the lower half of the chassis with the network ports) loses power independently of the Control Plane, the Data Plane cannot recover by itself. If both halves of the chassis lose power at the same time (a more-likely event), both halves reboot normally.

Best Practice: The Data Plane and Control Plane each have two power supplies. Connect one power supply from each Plane to one power source, and the other power supply from each Plane to an alternate power source.

Recovery: Stop and restart power on the Control Plane (the upper half of the ARX). This causes both modules to power up in the proper sequence.

File History Query Requires either File or Path name. (34523)
If you are on the File History Query page, and you leave the Path and File fields empty, and then press Query, it won't work and no error returns.

Workaround: Simply enter a Path or a File name, or both.

In the CLI and in the ARX Manager GUI, the "collect all" target file for nfs on VIP multi-protocol volume fails. (34695)
In a multi-protocol environment, if you specify an nfs target for the "collect all" command or the "copy" command, the target file will not be created.

Workaround: In a multi-protocol environment, specify a cifs target for the "collect all" command or the "copy" command. The target file will then be created.

The copy namespace command does not work on direct (presentation) mapped volumes. (34692 )
The interface that copy namespace uses to copy to cifs file servers does not support direct (presentation) mapped volumes.

Workaround: None.

On the ARX 4000, CoreCollector code has been change and may display old cores that were never collected and reported. (34722)
The new CoreCollector code now correctly reports all cores from the current release and previous releases. It may find cores that were never collected and reported.

When using "copy to a namespace" from a backup (peer) switch an incorrect error message displays. (34817)
The message you see is:% ERROR: CIFS_CONNECT_BADPATH_COPY_NAMESPACE (40960205): Unable to create file 'procdat' in volume '/max1-VOL1' in namespace 'max1'. Reason:Unable to establish a network connection.

Workaround: None. Copying to a namespace from a backup switch is not supported.

The GUI process uses 100% of CPU 1.1 on an ARX with thousands of reports. (31068)

The no monitor module CLI command does not completely disengage its network ports from their port-mirroring roles. (30435)
After you stop port mirroring from one network port to another, the ports retain some of their internal "mirroring" state. This prevents you from performing valid actions on the ports, such as adding them to a channel.

Workaround: Reboot the ARX after you use the no monitor module CLI command. You can use the priv-exec reload command to reboot the ARX from the CLI.

UTF-8 Chinese characters are truncated in namespace name. (30941)
If a user enters Chinese characters that exceed the GUI's limit for any input field, the GUI will not issue an error message but instead simply truncates the input.

The GUI input fields limit input based on characters and not bytes. When entering multi-byte characters, the input may be truncated if the total number of bytes representing the characters exceed the internal byte limit.

The CLI "show clock" output does not always show the correct time after a time-zone change. (24526)
You can use the clock timezone CLI command to set the time zone of the ARX. On rare occasions, the output from the show clock command does not show the correct time after this change. For example:

ARXa500# clock set 14:43:00 01/11/2007
ARXa500# show clock

        Local time:  Thu Jan 11 14:43:02 2007 EST -0500 America New_York
    Universal time:  Thu Jan 11 19:43:02 2007 UTC
ARXa500# config
ARXa500(cfg)# clock timezone America Denver
ARXa500(cfg)# show clock
        Local time:  Thu Jan 11 14:43:13 2007 EST -0500 America Denver
    Universal time:  Thu Jan 11 19:43:13 2007 UTC

The time does not conform to the new time zone, though the correct new time zone (America Denver) does appear in the output.

Workaround: Log out of the CLI and log back in.

During the hour of transition from daylight-savings time to standard time, the clock set CLI command incorrectly interprets times in some time zones. (24709)
Times are ambiguous in the hour when daylight-savings time reverts to standard time, once per year. Suppose the transition occurs at 3 AM on the day of the daylight-savings change: time passes from 3 to 4 AM in daylight-savings time, then the clock goes back to 3 AM for standard time, and then time passes from 3 to 4 AM again. In some time zones, if you reset the clock to a time between 3 and 4 AM, the clock set command may not interpret your time correctly. If this occurs, the ARX assumes that the transition to standard time has already occurred.

This only occurs in time zones that are East of the Prime Meridian, with positive offsets from UTC.

Workaround: Avoid the clock set command during the day and hour of transition.

The CLI displays unintended errors if you interrupt the copy CLI command (with <Ctrl-C>) during the file transfer. (32531)
The CLI copy command prints the following messages while it transfers a large file to or from the ARX:

% INFO: Transferred nnn of total megabytes; still copying . . .

If you press <Ctrl-C> while the CLI is printing these messages, some internal processes continue after the overall copy process halts. After 20-30 seconds, the CLI displays the following errors from those sub-processes:

gunzip: stdin: unexpected end of file
acrypt: Error, uncompress failed(256).

No output appears for the show statistics namespace fastpath CLI command. (34834)
This CLI command is designed to print statistics for every namespace on the ARX. It only prints statistics for specific namespaces. The CLI Maintenance Guide and the CLI Reference Guide incorrectly document the full, intended output for the command.

An ARX4000 does not support jumbo frames with 4.1.0 software and older firmware. (32103)
On an ARX4000 that is running 4.1.0 or later software with an earlier version of firmware, NSM cores fail if they are configured for jumbo frames. (You can enable or disable jumbo frames with the [no] jumbo mtu CLI command.)

Workaround: A workaround is only necessary if you upgrade an ARX4000 from Release 4.0.0 or earlier. In this case, upgrade the ARX4000 with the latest firmware as part of the installation process. For installation instructions, including the method for upgrading firmware, refer to the Upgrading Software chapter in the CLI Maintenance Guide.

The ARX cannot send E-mail messages through the out-of-band (OOB) management interface. NTP, DNS, RADIUS, and snapshot-management services (SSH and RSH) are also unsupported through the OOB interface. (24595)
All e-mail notifications from the ARX go out through an in-band (VLAN) management interface, configured with the interface vlan CLI command. At least one in-band-management interface must have a route to the E-mail server for E-mail notifications to function. The same applies to NTP, DNS, and RADIUS services, as well as SSH and RSH for managing filer snapshots.

Workaround: Use the cfg-mode ip route command (without the mgmt flag) to add a static IP route to the E-mail server(s), NTP server(s), DNS server(s), and/or RADIUS servers. All filers and file servers must have a route to be useable by the ARX at all, so this is less likely to be an issue for SSH and RSH.

Spurious errors appear in the syslog after an NSM failover. (25782)
NSM processors have redundant peers, even in an ARX that is not configured for overall redundancy. If an NSM processor fails, its peer processes packets for both. If nsm recovery is enabled, the failed processor comes back online and waits to take over for the running processor. The failed processor may repeatedly put the following message in the syslog:

 NAT rule TCP/ip-address:port for remote action ip-address-2:port-2 type 3 not found.

This syslog message is spurious.

Under very rare circumstances, the ARX may block administrative logins after a reboot. (32537)
An ARX in the F5-Development laboratory did not allow administrative logins after a reboot. Logins to the serial-Console port always timed out after entering the administrative password, and logins to the Out-of-Band Management port (typically labelled "MGMT") were rejected with this error message:

ssh_exchange_identification: Connection closed by remote host

F5 Development has been unable to reproduce this problem, despite hundreds of reboots. We note it here until the problem is proven to be unreproducible at any customer site.

Recovery: Power cycle the ARX.

The ARX erroneously allows you to assign the same secondary-IP address to multiple file-server configurations. (33211)
Two different file-servers (called "filers" in the CLI) cannot use the same IP address, but the ARX permits this mis-configuration.

You must separately export a CIFS managed volume if you use it as a "managed volume" in a CIFS presentation volume. (21231, 24359)
If a CIFS-managed volume is used as a managed volume in a CIFS-presentation volume, its CIFS front-end service must export the managed volume separately. This is in addition to the export for the presentation (or direct) volume. (The same CIFS service must export both volumes.)

A client IP address remains in the output of show nfs-service mounts after the client unmounts. (24478)
The output of the show nfs-service mounts command is a table of NFS mounts from client machines. For each currently-active client mount, the table displays the Global Server, the mount point, the VIP, and the client IP address.

When the client is unmounted, there may be a slight lag in the update of table information, and a repeat of the show nfs-service mounts command may show the client still mounted.

Workaround: Retry the show nfs-service mounts command.

Snapshot rule spuriously reports that it failed when it gets a minor communication error. (32814)
A snapshot rule pauses a volume's policy migrations while it runs. When the rule completes its filer snapshots, it tells the policy engine to resume its standard migrations. The snapshot rule erroneously reports that it failed if the policy engine fails to respond to this "resume" request. The failure appears in the snapshot report, along with the following message at the bottom of the report:

Unable to notify policy engine to resume any active migrations.

The policyRuleRunSuspend trap does not indicate the cause of the policy suspension. (32756)
An ARX rule may be suspended manually, through a CLI or GUI instruction, or because its schedule has a limited duration that has expired. The trap does not currently indicate whether the suspension is manual or scheduled.

A shadow-copy rule runs indefinitely (instead of terminating immediately) when the RON connection to the target share fails. (32110)
A shadow-copy rule should fail as soon as the RON connection to the target filer fails. Instead, it continues indefinitely, waiting for the RON connection to return.

NSCK reports do not identify "marked" multi-protocol directories where you should run a sync files operation. (23891)
Some multi-protocol (NFS and CIFS) directories are "marked" for special processing. These directories contain files and/or subdirectories one of these naming issues:

  • the name resembles a Filer-Generated Name (FGN, such as "myfile~1.txt"), or
  • the name produces an FGN on its back-end filers (such as "my:file.txt," or "MYFILE" in the same directory as "myfile").

If a directory is marked with one of these naming issues, the volume performs extra processing whenever a client tries to introduce an entry with the other naming issue. Depending on the outcome of the processing, the new client entry could become NFS-only (inaccessible to CIFS clients). Refer to the CLI Maintenance Guide for details.

Clients can resolve these issues by accessing the volume through its VIP and renaming the directory's entries. However, the directory mark persists after all of its child entries have been correctly renamed; you use the sync files CLI command to remove the mark.

The issue is that there are no reports that identify a directory as "marked" after its entries have been correctly renamed.

Workaround: Use sync files to clear the directory mark immediately after renaming its entries.

Contacting F5 Networks

  F5 Online Knowledge Base: http://support.f5.com/
F5 Services Support Online: https://websupport.f5.com/
Telephone: http://www.f5.com/training-support/customer-support/contact/

For additional information, please visit http://www.f5.com.

[ Top ]

Was this resource helpful in solving your issue?




NOTE: Please do not provide personal information.



Incorrect answer. Please try again: Please enter the words to the right: Please enter the numbers you hear:

Additional Comments (optional)